{"id":438,"date":"2019-03-21T13:04:46","date_gmt":"2019-03-21T16:04:46","guid":{"rendered":"https:\/\/www.shaletechsolutions.com\/?p=438"},"modified":"2026-08-04T10:31:33","modified_gmt":"2026-08-04T13:31:33","slug":"autocalcimeter-model-442","status":"publish","type":"post","link":"https:\/\/www.shaletechsolutions.com\/es\/autocalcimeter-model-442\/","title":{"rendered":"AutoCalcimeter Model 442"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"438\" class=\"elementor elementor-438\">\n\t\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5b7eab6a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5b7eab6a\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1d5d5ac9\" data-id=\"1d5d5ac9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-489fbe3c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"489fbe3c\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3ca03fb9\" data-id=\"3ca03fb9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-5cf4f4a1\" data-id=\"5cf4f4a1\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7322a358 elementor-widget elementor-widget-toggle\" data-id=\"7322a358\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1931\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1931\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Data Sheets<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1931\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1931\"><ul>\n<li><a href=\"http:\/\/www.shaletechsolutions.com\/es\/Drilling_Fluid_Testing\/Calcimeters\/AutoCalcimeter_Model_442_DS.pdf\/\">AutoCalcimeter Model 442<\/a><\/li>\n<\/ul><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1932\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-1932\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Procedures & Manuals<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1932\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-1932\"><ul>\n<li><a href=\"http:\/\/www.shaletechsolutions.com\/es\/Drilling_Fluid_Testing\/Calcimeters\/AutoCalcimeterManual_PM.pdf\/\">Manual for AutoCalcimeter<\/a><\/li>\n<\/ul><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1655b7b3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1655b7b3\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-188e17fe\" data-id=\"188e17fe\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-750b4d16 elementor-widget elementor-widget-text-editor\" data-id=\"750b4d16\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<!-- wp:paragraph -->\n<p>Shale Tech Solutions SRL distribuidor exclusivo de FANN para la Argentina<\/p>\n<!-- \/wp:paragraph --><!-- wp:paragraph -->\n<p>The AutoCalcimeter determines the amount of calcium carbonate (CaCO3 or calcite) and calcium magnesium carbonate (CaMg(CO3)2 or dolomite) in alkaline earth carbonate samples &#8211; such as oil well cores or drill cuttings. Calcite or dolomite buildup in drilling fluids and water treatment process causes scaling problems, and data from the Fann AutoCalcimeter can help determine the most optimal chemical treatment.<\/p>\n<!-- \/wp:paragraph --><!-- wp:paragraph -->\n<p>This instrument is in compliance with ASTM D 4373-84: Standard Test Method for Calcium Carbonate Content in Soils.<\/p>\n<!-- \/wp:paragraph --><!-- wp:paragraph -->\n<p><strong>Features<\/strong><\/p>\n<!-- \/wp:paragraph --><!-- wp:list -->\n<ul>\n<li>Automatic and accurate dispensing of HCl when test begins<\/li>\n<li>Automatic stirring of sample with acid, by built-in stirring mechanism<\/li>\n<li>Automatic recording of pressure readings and elapsed time internally and on USB flash drive<\/li>\n<li>Automatic calcite and dolomite percentage reporting, with all calculations performed internally<\/li>\n<li>Real-time clock stamps date and time<\/li>\n<li>Data communication port for integration to computer<\/li>\n<\/ul>\n<!-- \/wp:list --><!-- wp:paragraph -->\n<p><strong>Application<\/strong><br \/>Samples containing calcite and dolomite are reacted with 1 Normal HCl to measure the released CO2, in a sealed reaction cell. A calibration curve (determined using a pure calcium carbonate reagent) is used to relate the pressure to the weight of the calcium carbonate in the sample. Several weights of the sample are utilized, to ensure the most accurate curve, and pressures for the curve are measured and stored automatically when running the appropriate calibration sample size.<\/p>\n<!-- \/wp:paragraph --><!-- wp:paragraph -->\n<p><strong>Recording and Interpreting Test Data<\/strong><br \/>With a USB flash drive connected, the AutoCalcimeter will record the test data onto the USB drive in .csv file format. If the Flash drive is not present the data is still recorded in the internal memory. The AutoCalcimeter records the last 20 tests; this data can be downloaded using the transfer button on the keypad.<\/p>\n<!-- \/wp:paragraph --><!-- wp:paragraph -->\n<p>Test data can be interpreted using calibration curves for the pressure of calcite and dolomite. This material is provided in the included instruction manual.<\/p>\n<!-- \/wp:paragraph --><!-- wp:table -->\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>Dimensions (W x D x H)<\/td>\n<td>16 in x 9 in x 9.5in<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>15 lb<\/td>\n<\/tr>\n<tr>\n<td>Power Supply<\/td>\n<td>100 to 240 VAC, 50-60 hz, 75 watts<\/td>\n<\/tr>\n<tr>\n<td>Ports<\/td>\n<td>Power, RS485 serial, USB<\/td>\n<\/tr>\n<tr>\n<td>Data Communication<\/td>\n<td>USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<!-- \/wp:table --><!-- wp:paragraph -->\n<p><strong><em>Ordering Information<\/em><\/strong><br \/><strong>Part No. 102452754 AutoCalcimeter Model 442<br \/><\/strong>Includes plastic carrying case, mortar and pestle, pocket digital Weighing scale, CaCO3 compound, HCl, and instruction manual<\/p>\n<!-- \/wp:paragraph -->\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Data Sheets AutoCalcimeter Model 442 Procedures &#038; Manuals Manual for AutoCalcimeter Shale Tech Solutions SRL distribuidor exclusivo de FANN para la Argentina The AutoCalcimeter determines&hellip;<\/p>","protected":false},"author":1,"featured_media":440,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>AutoCalcimeter Model 442 | Shale Tech Solutions<\/title>\n<meta name=\"description\" content=\"The AutoCalcimeter determines the amount of calcium carbonate and calcium magnesium carbonate in alkaline earth carbonate samples.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.shaletechsolutions.com\/es\/autocalcimeter-model-442\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AutoCalcimeter Model 442 | Shale Tech Solutions\" \/>\n<meta property=\"og:description\" content=\"The AutoCalcimeter determines the amount of calcium carbonate and calcium magnesium carbonate in alkaline earth carbonate samples.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.shaletechsolutions.com\/es\/autocalcimeter-model-442\/\" \/>\n<meta property=\"og:site_name\" content=\"Shale Tech Solutions\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-21T16:04:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-04T13:31:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.shaletechsolutions.com\/wp-content\/uploads\/2019\/03\/AutoCalcimeter.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"173\" \/>\n\t<meta property=\"og:image:height\" content=\"260\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"author\" content=\"sDesuque\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"sDesuque\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/\"},\"author\":{\"name\":\"sDesuque\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/#\/schema\/person\/96232e62b8aceff1ac96723ed96ba91d\"},\"headline\":\"AutoCalcimeter Model 442\",\"datePublished\":\"2019-03-21T16:04:46+00:00\",\"dateModified\":\"2026-08-04T13:31:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/\"},\"wordCount\":371,\"publisher\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/#organization\"},\"articleSection\":[\"Drilling Fluids Testing\"],\"inLanguage\":\"es-AR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/\",\"url\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/\",\"name\":\"AutoCalcimeter Model 442 | Shale Tech Solutions\",\"isPartOf\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/#website\"},\"datePublished\":\"2019-03-21T16:04:46+00:00\",\"dateModified\":\"2026-08-04T13:31:33+00:00\",\"description\":\"The AutoCalcimeter determines the amount of calcium carbonate and calcium magnesium carbonate in alkaline earth carbonate samples.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/#breadcrumb\"},\"inLanguage\":\"es-AR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\/\/www.shaletechsolutions.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"AutoCalcimeter Model 442\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/#website\",\"url\":\"https:\/\/www.shaletechsolutions.com\/\",\"name\":\"Shale Tech Solutions\",\"description\":\"Equipamiento para Laboratorios de An\u00e1lisis de Fluidos y Cementaci\u00f3n\",\"publisher\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.shaletechsolutions.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es-AR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/#organization\",\"name\":\"Shale Tech Solutions\",\"alternateName\":\"STS\",\"url\":\"https:\/\/www.shaletechsolutions.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-AR\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.shaletechsolutions.com\/wp-content\/uploads\/2026\/06\/IsologoSTS.png\",\"contentUrl\":\"https:\/\/www.shaletechsolutions.com\/wp-content\/uploads\/2026\/06\/IsologoSTS.png\",\"width\":2185,\"height\":1063,\"caption\":\"Shale Tech Solutions\"},\"image\":{\"@id\":\"https:\/\/www.shaletechsolutions.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/shale-tech-solutions\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/#\/schema\/person\/96232e62b8aceff1ac96723ed96ba91d\",\"name\":\"sDesuque\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-AR\",\"@id\":\"https:\/\/www.shaletechsolutions.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1c57cf4b21d807810e5afb73fabe345a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1c57cf4b21d807810e5afb73fabe345a?s=96&d=mm&r=g\",\"caption\":\"sDesuque\"},\"url\":\"https:\/\/www.shaletechsolutions.com\/es\/author\/sdesuque\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AutoCalcimeter Model 442 | Shale Tech Solutions","description":"The AutoCalcimeter determines the amount of calcium carbonate and calcium magnesium carbonate in alkaline earth carbonate samples.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.shaletechsolutions.com\/es\/autocalcimeter-model-442\/","og_locale":"es_ES","og_type":"article","og_title":"AutoCalcimeter Model 442 | Shale Tech Solutions","og_description":"The AutoCalcimeter determines the amount of calcium carbonate and calcium magnesium carbonate in alkaline earth carbonate samples.","og_url":"https:\/\/www.shaletechsolutions.com\/es\/autocalcimeter-model-442\/","og_site_name":"Shale Tech Solutions","article_published_time":"2019-03-21T16:04:46+00:00","article_modified_time":"2026-08-04T13:31:33+00:00","og_image":[{"width":173,"height":260,"url":"https:\/\/www.shaletechsolutions.com\/wp-content\/uploads\/2019\/03\/AutoCalcimeter.gif","type":"image\/gif"}],"author":"sDesuque","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"sDesuque","Tiempo de lectura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/#article","isPartOf":{"@id":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/"},"author":{"name":"sDesuque","@id":"https:\/\/www.shaletechsolutions.com\/#\/schema\/person\/96232e62b8aceff1ac96723ed96ba91d"},"headline":"AutoCalcimeter Model 442","datePublished":"2019-03-21T16:04:46+00:00","dateModified":"2026-08-04T13:31:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/"},"wordCount":371,"publisher":{"@id":"https:\/\/www.shaletechsolutions.com\/#organization"},"articleSection":["Drilling Fluids Testing"],"inLanguage":"es-AR"},{"@type":"WebPage","@id":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/","url":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/","name":"AutoCalcimeter Model 442 | Shale Tech Solutions","isPartOf":{"@id":"https:\/\/www.shaletechsolutions.com\/#website"},"datePublished":"2019-03-21T16:04:46+00:00","dateModified":"2026-08-04T13:31:33+00:00","description":"The AutoCalcimeter determines the amount of calcium carbonate and calcium magnesium carbonate in alkaline earth carbonate samples.","breadcrumb":{"@id":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/#breadcrumb"},"inLanguage":"es-AR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.shaletechsolutions.com\/autocalcimeter-model-442\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.shaletechsolutions.com\/"},{"@type":"ListItem","position":2,"name":"AutoCalcimeter Model 442"}]},{"@type":"WebSite","@id":"https:\/\/www.shaletechsolutions.com\/#website","url":"https:\/\/www.shaletechsolutions.com\/","name":"Shale Tech Solutions","description":"Equipamiento para Laboratorios de An\u00e1lisis de Fluidos y Cementaci\u00f3n","publisher":{"@id":"https:\/\/www.shaletechsolutions.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.shaletechsolutions.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es-AR"},{"@type":"Organization","@id":"https:\/\/www.shaletechsolutions.com\/#organization","name":"Shale Tech Solutions","alternateName":"STS","url":"https:\/\/www.shaletechsolutions.com\/","logo":{"@type":"ImageObject","inLanguage":"es-AR","@id":"https:\/\/www.shaletechsolutions.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.shaletechsolutions.com\/wp-content\/uploads\/2026\/06\/IsologoSTS.png","contentUrl":"https:\/\/www.shaletechsolutions.com\/wp-content\/uploads\/2026\/06\/IsologoSTS.png","width":2185,"height":1063,"caption":"Shale Tech Solutions"},"image":{"@id":"https:\/\/www.shaletechsolutions.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/shale-tech-solutions\/"]},{"@type":"Person","@id":"https:\/\/www.shaletechsolutions.com\/#\/schema\/person\/96232e62b8aceff1ac96723ed96ba91d","name":"sDesuque","image":{"@type":"ImageObject","inLanguage":"es-AR","@id":"https:\/\/www.shaletechsolutions.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1c57cf4b21d807810e5afb73fabe345a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1c57cf4b21d807810e5afb73fabe345a?s=96&d=mm&r=g","caption":"sDesuque"},"url":"https:\/\/www.shaletechsolutions.com\/es\/author\/sdesuque\/"}]}},"_links":{"self":[{"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/posts\/438"}],"collection":[{"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/comments?post=438"}],"version-history":[{"count":7,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/posts\/438\/revisions"}],"predecessor-version":[{"id":3484,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/posts\/438\/revisions\/3484"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/media\/440"}],"wp:attachment":[{"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/media?parent=438"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/categories?post=438"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.shaletechsolutions.com\/es\/wp-json\/wp\/v2\/tags?post=438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}